  • Reliable results on 18 vital parameters
  • Spend less time in front of the analyser with FLEXQ
  • Configured to meet your needs

Reliable, Efficient, Flexible

The ABL800 FLEX blood gas analyser utilises automation to deliver trusted results, while supporting operational efficiency.

Amidst pressures to optimise resources and personnel, equip and empower busy laboratory staff with:
  • Results you can trust
  • Improved workflow
  • A flexible partner to meet your needs
 
 

"Drop-n-Go" on the FLEXQ 

Fully automatic scanning, mixing, and aspiration of blood samples

 

Easy to operate screen

Intuitive interface with highly responsive tablet-like interaction

 

Additional clinical insight

Measure up to 18 critical parameters on one sample to support fast diagnosis

 

Autocheck

Supporting compliance with automatic QC

Parameters measured

Blood gases: 
pH

Potential of hydrogen

The degree of acidity or alkalinity of any liquid (including blood) is a function of its hydrogen ion concentration [H+], and pH is simply a way of expressing hydrogen ion activity. The relationship between pH and hydrogen ion concentration is described thus:

pH = -log aH+
where aH+ is hydrogen ion activity.

Low pH is associated with acidosis and high pH with alkalosis [1].

Read more

 

1. CLSI. Blood gas and pH analysis and related measurements; Approved Guidelines. CLSI document CA46-A2, 29, 8. Clinical and Laboratory Standards Institute, 940 West Valley Road, Suite 1400, Wayne, Pennsylvania 19087-1898 USA, 2009.

, pCO2

Partial pressure of carbon dioxide

Carbon dioxide (CO2) is an acidic gas; the amount of CO2 in blood is largely controlled by the rate and depth of breathing or ventilation. pCO2 is the partial pressure of CO2 in blood. It is a measure of the pressure exerted by that small portion (~5 %) of total CO2 that remains in the gaseous state, dissolved in the blood plasma. pCO2 is the respiratory component of acid-base balance and reflects the adequacy of pulmonary ventilation. The severity of ventilator failure as well as the chronicity can be judged by the accompanying changes in acid-base status [1].

Read more

 

1. Higgins C. Parameters that reflect the carbon dioxide content of blood. www.acutecaretesting.org Oct 2008.

, pO2

Partial pressure of oxygen

The amount of oxygen in blood is controlled by many variables, e.g. ventilation/perfusion. pO2 is the partial pressure of oxygen in a gas phase in equilibrium with the blood. pO2 only reflects a small fraction (1 – 2 %) of total oxygen in blood that is dissolved in blood plasma [1]. The remaining 98 – 99 % of oxygen present in blood is bound to the hemoglobin in the erythrocytes. pO2 primarily reflects the oxygen uptake in the lungs. 

Read more

 

1. Wettstein R, Wilkins R. Interpretation of blood gases. In: Clinical assessment in respiratory care, 6th ed. St. Louis: Mosby, 2010.

Metabolites: 
cGlu

Glucose

Glucose, the most abundant carbohydrate in human metabolism, serves as the major intracellular energy source (see lactate). Glucose is derived principally from dietary carbohydrate, but it is also produced – primarily in the liver and kidneys – via the anabolic process of gluconeogenesis, and from the breakdown of glycogen (glycogenolysis). This endogenously produced glucose helps keep blood glucose concentration within normal limits, when dietary-derived glucose is not available, e.g. between meals or during periods of starvation.

Read more

, cLac

Lactate

Lactate, the anion that results from dissociation of lactic acid, is an intracellular metabolite of glucose. It is produced by skeletal muscle cells, red blood cells (erythrocytes), the brain, and other tissues during anaerobic energy production (glycolysis). Lactate is formed in the intracellular fluid from pyruvate; the reaction is catalyzed by the enzyme lactate dehydrogenase (LDH) [1].

 

1. Robergs RA, Ghiasvand F, Parker D. Biochemistry of exercise-induced metabolic acidosis. Am J Physiol Regul Integr Comp Physiol 2004; 287: R502-16.

, cCrea

Creatinine

Creatinine is an endogenous waste product of muscle metabolism, derived from creatine, a molecule of major importance for energy production within muscle cells. Creatinine is removed from the body in urine and its concentration in blood reflects glomerular filtration and thereby kidney function.

Read more

Electrolytes: 
cCa2+

Calcium

The calcium ion (Ca2+) is one of the most prevalent cations in the body, where approximately 1 % is present in the extracellular fluid of blood. Ca2+ plays a vital role for bone mineralization and many cellular processes, e.g. contractility of the heart and the skeletal musculature, neuromuscular transmission, hormone secretion and action in various enzymatic reactions such as, e.g. blood coagulation.

Read more

, cCl-

Chloride

Chloride (Cl-) is the major anion in the extracellular fluid and one of the most important anions in blood. The main function of Cl- is to maintain osmotic pressure, fluid balance, muscular activity, ionic neutrality in plasma, and help elucidate the cause of acid-base disturbances.

Read more

, cK+

Potassium

Potassium (K+) is the major cation in the intracellular fluid, where it has a 25 - 37-fold higher concentration (∼150 mmol/L in tissue cells, ∼105 mmol/L in erythrocytes) than in the extracellular fluid (∼4 mmol/L) [1, 2]. K+ has several vital functions in the body, e.g. regulation of neuromuscular excitability, regulation of heart rhythm, regulation of intracellular and extracellular volume and acid-base status.

Read more

 

1. Burtis CA, Ashwood ER, Bruns DE. Tietz textbook of clinical chemistry and molecular diagnostics. 5th ed. St. Louis: Saunders Elsevier, 2012. Engquist A. Fluids/Electrolytes/Nutrition. 1st ed. Copenhagen: Munksgaard, 1985.
2. Engquist A. Fluids/Electrolytes/Nutrition. 1st ed. Copenhagen: Munksgaard, 1985.

, cNa+

Sodium

Sodium (Na+) is the dominant cation in the extracellular fluid, where it has a 14-fold higher concentration (∼140 mmol/L) than in the intracellular fluid (∼10 mmol/L). Na+ is a major contributor of the osmolality of the extracellular fluid and its main function is largely in controlling and regulating water balance, and maintaining blood pressure. Na+ is also important for transmitting nerve impulses and activating muscle concretion.

Read more

Oximetry: 
COHb

Carboxyhemoglobin

FMetHb is the fraction of total hemoglobin (ctHb) that is present as methemoglobin (MetHb). By convention the fraction is expressed as a percentage (%).

In the range of 0 – 60 % COHb in arterial (COHb(a)) and venous blood (COHb(v)) is similar, i.e. either venous or arterial blood may be analyzed [1]. In most medical texts FCOHb(a) is referred to as simply COHb.

Read more

 

1. Lopez DM, Weingarten-Arams JS, Singer LP, Conway EE Jr. Relationship between arterial, mixed venous and internal jugular carboxyhemoglobin concentrations at low, medium and high concentrations in a piglet model of carbon monoxide toxicity. Crit Care Med 2000; 28: 1998-2001.

, ctBil

Bilirubin

Bilirubin is the yellow breakdown product of the degradation of the heme group of hemoglobin. It is transported in blood from its site of production – the reticuloendothelial system – to the liver, where it is biotransformed before excretion in bile. Jaundice, the pathological yellow discoloration of skin, is due to abnormal accumulation of bilirubin in the tissues, and is always associated with elevated blood concentration of bilirubin (hyperbilirubinemia).

Read more

, ctHb

Total hemoglobin

The concentration of total hemoglobin (ctHb) in blood includes oxyhemoglobin (cO2Hb), deoxyhemoglobin (cHHb), as well as the dysfunctional hemoglobin species that are incapable of binding oxygen:

carboxyhemoglobin (cCOHb) (see COHb), methemoglobin (cMetHb) (see MetHb) and sulfhemoglobin (cSulfHb).

Thus:

ctHb = cO2Hb + cHHb + cCOHb + cMetHb + cSulfHb

The rare sulfHb is not included in the reported c tHb in most oximeters.

Read more

, FHbF

Fraction of fetal hemoglobin

FHbF in total hemoglobin in blood.

Read more

, FHHb

Fraction of deoxyhemoglobin


FHHb in total hemoglobin in blood.

, MetHb

Methemoglobin

FMetHb is the fraction of total hemoglobin (ctHb) that is present as methemoglobin (MetHb). By convention the fraction is expressed as a percentage (%) [1].

In most medical text boxes MetHb(a) is referred to as simply methemoglobin (MetHb).

Read more

 

1. CLSI. Blood gas and pH analysis and related measurements; Approved Guidelines. CLSI document CA46-A2, 29, 8. Clinical and Laboratory Standards Institute, 940 West Valley Road, Suite 1400, Wayne, Pennsylvania 19087-1898 USA, 2009.

, sO2

Oxygen saturation

Oxygen saturation (sO2) is the ratio of oxyhemoglobin concentration to concentration of functional hemoglobin (i.e. oxyhemoglobin (O2Hb) and deoxyhemoglobin (HHb) capable of carrying oxygen [1].

The sO2 reflects utilization of the currently available oxygen transport capacity.

In arterial blood 98 – 99 % of oxygen is transported in erythrocytes bound to hemoglobin. The remaining 1–2 % of the oxygen transported in blood is dissolved in the blood plasma – this is the portion reported as partial pressure of oxygen (pO2) [2].

Read more

 

1. CLSI. Blood gas and pH analysis and related measurements; Approved Guidelines. CLSI document CA46-A2, 29, 8. Clinical and Laboratory Standards Institute, 940 West Valley Road, Suite 1400, Wayne, Pennsylvania 19087-1898 USA, 2009.
2. Higgins C. Parameters that reflect the carbon dioxide content of blood. www.acutecaretesting.org Oct 2008.

, FO2Hb

Fraction of oxyhemoglobin

FO2Hb in total hemoglobin in blood.

Read more

The equipment I use in my work must be trustworthy, user-friendly and reliable […] For more than ten years, we’ve been using the ABL800 series from Radiometer. It works very well for us.

- Anna-Karin Ståhlberg, Biomedical Analyst, Clinical Chemistry Laboratory, Halland´s Hospital Halmstad, Sweden

How can we help you facilitate Seamless Diagnostics?

Support sample integrity with automatic mixing

Enable more accurate haemoglobin results with FLEXQ and safePICO syringes

Achieve reliable results from low volume samples

Leverage FLEXMODE for results from samples of just 35μL

Select the parameters you use in practice

Customise analysers to measure the parameters suited to your clinical practice

Built-in cyber security

Help protect patient data, reduce the risk of cyber attacks and consequent disruption to analyser operation

Save time with FLEXQ's Drop-n-Go

Use safePICO syringes with FLEXQ for hands-free analysis of up to three successive samples

Reduce patient-sample mix up

Ensure correct patient-sample identification every time and improve workflow with 1st Automatic

Confidently meet health care challenges with a trusted analyser

The ABL800 FLEX is a reference point for blood gas testing and has specific features designed to:

  • Support sample integrity
  • Mitigate the influence of potentially interfering substances on co-oximetry and creatinine
  • Provide reliable results using dedicated measuring modes

Supporting an improved blood gas workflow with efficient automation

Drop-n-Go helps you reclaim time previously spent in front of the analyser. Place up to three safePICO syringes on the FLEXQ and you're free to Go. Your samples will be scanned, mixed, aspirated, analysed and reported, automatically.


Combine your ABL800 FLEX and safePICO syringes with AQURE's FLEXLINK system to utilize 1st Automatic. The connected solution registers patient, operator and sample IDs at the bedside, while FLEXLINK links these data together. An example of how it could expedite your workflow is shown below.

Improve your blood gas workflow with automation and connected solutions

A flexible partner in meeting your needs

The ABL800 FLEX supports fluctuating blood gas testing demands with individual and replaceable consumables. The analyser is adaptable, so you can customise it to meet your specific parameter and configuration needs.

To find out more, contact your local Radiometer representative. We're here to support you in constructing your unique setup.

Built-in cybersecurity helps increase uptime

The ABL800 FLEX has built-in cyber security features to help secure patient data and reduce the risk of cyber attacks and any consequent disruption to analyser operation.

Our cyber security model operates as a multi-layered defense system, alongside hospital security measures. Based on Microsoft-supported operating systems, our proactive model includes Application Control, Patch management and system updates tested prior installation. Visit our Security Packages to learn more.

The acute care testing handbook

Download the free guide on blood gases and other critical parameters in acute care testing.

Let us help you prevent preanalytical errors

Find out more about the most common preanalytical errors and how to prevent them.

Guiding your blood gas testing

Through three educational videos, you’ll experience why blood gas analysis is important in three critical patient cases covering COPD, intoxication and sepsis. Further, a set of three how-to videos will guide you in performing an arterial puncture, understanding the acid-base balance in the blood and to reading the blood gas report.

MAPSSS-000936 R1

Cookies are used on this website

Use of cookies
Confirm your account with Radiometer

Please enter a valid email

CONTINUE
By submitting your e-mail you agree to the data policy notice
Radiometer is using Microsoft Azure Active Directory to authenticate customer access. If you are already registered you will be taken to Microsoft AD to sign in using your Microsoft AD credentials.
You are already registered
Radiometer is using Microsoft Azure AD to authenticate customer access. If you are already registered you will be taken to AZURE to sign in using your AZURE credentials.
Thank you

We will be sending an e-mail invitation to you shortly to sign in using Microsoft Azure AD.

Radiometer is using Microsoft Azure AD to authenticate customer access.
Sorry

It seems that your e-mail is not registered with us

Radiometer is using Microsoft Azure AD to authenticate customer access. If your e-mail is not registered with us please click CONTINUE and we will guide you through the sign-in process.
We have previously sent an invitation by e-mail

Please click "Get started" in the e-mail to complete the registration process

Radiometer is using Microsoft Azure AD to authenticate customer access.
Sorry

We were not able to process your request due to a communication error

Sorry

It seems this account has not been given access to the portal

Radiometer is using Microsoft AZURE Active Directory to authenticate users

Radiometer uses Azure AD to provide our customers and partners secure access to documents, resources, and other services on our customer portal.

If your organization is already using Azure AD you can use the same credentials to access Radiometer's customer portal.

Key benefits

       
  • Allow the use of existing Active Directory credentials
  •    
  • Single-sign on experience
  •    
  • Use same credentials to access future services    

Request access

You will receive an invitation to access our services via e-mail when your request  has been approved.

When you accept the invitation, and your organization is already using AZURE AD, you can use the same credentials to access Radiometer's customer portal. Otherwise, a one-time password will be sent via e-mail to sign in.

Effective Date January 20th, 2023 (last updated January 20th, 2023)

ABOUT THIS POLICY

Radiometer values your privacy and the protection of your personal data. This policy (“Policy”) explains how Radiometer its affiliates, subsidiaries or related companies, a full list of which can be located here (together, “Radiometer,”, “our”, “us,” or “we”), collects, uses, shares, transfers and processes data collected from or about you.

Personal Data” is any information that can be used to directly or indirectly identify an individual or that can be reasonably expected to link to an individual. This can include items such as name, address, telephone number, credit card details, email address, ID number, Internet Protocol (“IP”) address of an electronic device used by an individual, or other identifying code (even absent of other identifying information). Statistical and non-identifiable metric data are not considered Personal Data.

The Radiometer subsidiary, affiliate or related company with which you interact is, where applicable, the data controller (or equivalent under applicable law) responsible for the processing of your Personal Data. You can find a list of the relevant legal entities that act as data controllers in Appendix 1 to this Policy.

SCOPE

This Policy describes the types of Personal Data that we may collect, process or disclose about you and how you may govern this processing by exercising applicable legal rights. This Policy applies to both online and offline information collection, including your use of websites or subdomains operated by us, any mobile applications, when we provide products and/or services to you or notify you about prospective items of interest and in other situations where you interact with us in-person, by telephone or by mail where this Policy is posted or referenced.

There may be occasion where you have been provided with a circumstance-specific privacy notice that is separate from this policy, such as privacy notices for specific activities such as Recruitment. To the extent you were provided with a different notice, those notices apply and govern our interactions with you. If you provide Personal Data about parties other than yourself, you are responsible for ensuring their knowledge of how we will process their personal data, and, where applicable, obtaining any necessary consents required in advance.

Read more

Experience the Power of Seamless Diagnostics